InstallatIon anD maIntenance
VARMECA 30
Variable speed motor or geared motor
3776 en -
3.5.2.2 - 3-phase AC power supply in accordance with safety standard EN954-1 - category 1 with use of safety input
(1) if external potentiometer : resistance = 10 k
W
Note:
For single-phase standards, the power supply is connected to terminals l and n.
Qs: Fused isolator: Qs must be opened before any intervention on the electrical parts of the drive or motor.
aU: emergency stop button.
optional braking resistor. Dissipates the active power returned by the motor onto the drive Dc bus in the event of a driving machine.
Using the safety input means the motor can be stopped in freewheel mode without using a line contactor. the drive’s internal
principles are sufficiently safe to perform a stop using the safety input directly (category 1 of en954-1).
0-10 V/4-20mA
(1) speed reference
(local options or external ref.)
Motor PTC input
Local option indication
External fault input
Forward / Stop
Reverse / Stop
Selection of 0-10 V/4-20mA
speed reference
Indicator relay
0-10 V/4-20mA
(1) speed reference
(local options or external ref.)
Motor PTC input
Local option indication
External fault input
Forward / Stop
Reverse / Stop
Selection of 0-10 V/4-20mA
speed reference
Indicator relay
Safety contact
Mains supply
Mains supply
Braking resistor
(optional)
Jumper to be removed if
optional braking resistor
connected
Braking resistor
(optional)