Page 2 of 3
© 2020 Leotek Electronics USA LLC. GC_CV_EC_Installation Guide_09-03-2020.
GreenCobra
™
ComfortView
™
& E-Cobra
™
LED Street Light
Installation Guide
1
2
4
3
Step 5 - Adjust Drive Current/Light Output
Drive current should comply with designed illumination levels and circuit
loading. Consult with design engineer before changing. If a new drive current
or output code is required, open the connector and change the connection
according to the current selector or output selector label installed in the fixture.
Note: If the Fixed Drive Current (Fixed Output Code in J-Series) option or Control
Ready option was ordered, the drive current or the light output cannot be
changed. For ComfortView
TM
product, an output selector is used to adjust the
illumination levels and circuit loading. Please refer to ComfortView
TM
spec sheet
for specific details.
Electrical Wiring Connection
Step 6 -
Connect the green conductor to the ground chassis marked “G”(shown to the right of the terminal block).
Step 7 -
Connect the black conductor (Hot 1) to the input terminal marked “L”.
Step 8 -
Connect the white conductor (Neutral) or second black conductor (Hot 2) to the input terminal marked
“N”
according to Wiring Table.
Step 9
- Close the door.
Wiring Table
MV*
(120/220/277V)
HV*
(347/480V)
L
Hot 1
Hot 1
N
Neutral
Hot 2 (208V/240V)
Hot 2
G
Ground
Ground
LO
(If Available) Not Used for Input Voltage
* All Power Supplies are Auto-Sensing
Step 4 -
Securely tighten bolts to 16±2lbs-ft. (22Nm ± 3Nm) by alternating from bolt to bolt
in equal measured amounts of 25%
torque
. (See image below for tightening order) Ensure that the slip-fitter bracket does not tilt completely to one side and refrain
from unevenly tightening bolts, as it will cause cross-threading.
Step 10
- If luminaire is furnished with photocontrol receptacle,
install the photo
control or shorting cap.
WARNING:
Avoid tightening bolts unevenly, as it may cause cross-threading.
,