background image

 

 

 

FCC Notice

 

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant 
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency 
energy. It may cause harmful interference to radio communications if the equipment is not installed and 
used in accordance with the instructions. However, there is no guarantee that interference will not occur in 
a particular installation. If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

 

 

Reorient or relocate the receiving antenna.

 

 

Increase the separation between the equipment and receiver.

 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.

 

 

Consult the dealer or an experienced radio/TV technician for help.

 

 

Caution: Any changes or modifications not expressly approved by the grantee of this device could void 
the user's authority to operate the equipment.

 

 

Déclaration FCC

 

Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements 
numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour fournir 
une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel. Cet 
équipement génère, utilise, et peut émettre de l’énergie de fréquence radio et, s’il n’est pas installé et 
utilisé conformément au manuel d’instruction, peut perturber la réception radio. Cependant, il n’est pas 
garanti que l’équipement ne produira aucune interférence dans une installation particulière. Si cet 
équipement cause des interférences nuisibles à la réception radio ou télévisée, qui peuvent être 
déterminées en l’éteignant et le rallumant, l’utilisateur est encouragé à essayer de remédier au problème 
en prenant les mesures suivantes:

 

 

Réorienter ou déplacer l’antenne réceptrice.

 

 

Augmenter la distance entre l’équipement et le récepteur.

 

 

Connecter l’équipement à une prise secteur sur un circuit différent de celui utilisé par le récepteur.

 

 

Consulter le négociant ou un technicien radio/TV expérimenté.

 

 

Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de cet 
appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement.

 

 

CE Mark Warning

 

This is a Class-A product. In a domestic environment this product may cause radio interference in which 
case the user may be required to take adequate measures.

 

 

CE Mark Avertissement

 

Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en 
présence d'interférences radio.

 

 

This document is the current official release manual. Please check our website (www.leonton.com) for any 
updated manual or contact us by e-mail ([email protected]).

Summary of Contents for GINJ-0201-BT

Page 1: ...GINJ 0201 BT 12 T...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Page 4: ...sions 2 Front Panel 3 Top View 3 LED Indicators 4 Relay Contact Alarm Warning 4 Ethernet Ports 5 Cabling 6 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 7 Grounding Note 7 MOUNTING INSTALLA...

Page 5: ...trial markets like automation surveillance and vehicle industry Besides that with the fan less design this model series also works perfectly in polarized temperatures from 40 75 and undoubtedly become...

Page 6: ...tif de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convert...

Page 7: ...HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of GINJ 0201 BT 12 Series W x H x D is 30mm x 95mm x 75mm Figure 2 1 Physical Dimensions...

Page 8: ...3 below shows the top panel of the GINJ 0201 BT 12 Series Industrial Gigabit BT PoE Injector that is equipped with one 2 pin terminal block for relay contact alarm and 4 pin terminal block connectors...

Page 9: ...oE output budget Key trigger event 3 PoE over current per port Key trigger event 4 Cable short per port Key trigger event 5 One of the channels in Dual PD fail Notice When the relay is triggered becau...

Page 10: ...ght Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45 Pin...

Page 11: ...tive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten the wire clamp screws to...

Page 12: ...ct is shown below in Figure 2 6 Figure 2 6 Fault Alarm Contact Grounding Note Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connecti...

Page 13: ...IN Rail is pre installed on the industrial Ethernet injector from the factory If the DIN Rail is not on the unit please see Figure 3 1 to learn how to install the DIN Rail on it Figure 3 1 The Rear Si...

Page 14: ...IN Rail bracket is installed on the rear side of the injector insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Figure 3 2 Insert the Injector on the DIN Rail Step 4 Lightly...

Page 15: ...al Ethernet injector Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet injector Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 16: ...ing Installation section Step 4 Power on the industrial Injector and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Ple...

Page 17: ...t me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agit...

Page 18: ...t turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Leonton for tech...

Reviews: