background image

 

 

 

 

Caution:

 If the equipment is used in a manner not specified by the manufacturer, the 

protection provided by the equipment may be impaired.

 

 

Attention: 

Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la 

protection fournie par l'équipement peut être altérée.

 

 

 

 

Caution:

 The installation that the safety to any system incorporating the equipment is 

the responsibility of the assembler of the system.

 

 

Attention: 

L'installation que la sécurité de tout système intégrant l'équipement est de la 

responsabilité de l'assembleur du système.

 

 

 

 

Caution:

 This is an OPEN TYPE module and should be installed in a final safety enclosure 

characteristic.

 

 

Attention: 

Il s'agit d'un module de TYPE OUVERT et doit être installé dans une 

caractéristique finale d'enceinte de sécurité.

 

 

 

 

Caution:

 This device is intended for use indoor and at altitudes up to 2000 meters. 

 

 

Attention: 

Cet appareil est destiné à être utilisé en intérieur et à des altitudes allant 

jusqu'à 2000 mètres. 

 

 

 

 

Caution:

 Ambient Relative Humidity should be within the range of 5 and 95% (non-

condensing).

 

 

Attention: 

L'humidité relative ambiante doit être comprise entre 5 et 95% (sans 

condensation).

 

 

Summary of Contents for GINJ-0201-BT

Page 1: ...GINJ 0201 BT 12 T...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Page 4: ...sions 2 Front Panel 3 Top View 3 LED Indicators 4 Relay Contact Alarm Warning 4 Ethernet Ports 5 Cabling 6 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 7 Grounding Note 7 MOUNTING INSTALLA...

Page 5: ...trial markets like automation surveillance and vehicle industry Besides that with the fan less design this model series also works perfectly in polarized temperatures from 40 75 and undoubtedly become...

Page 6: ...tif de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convert...

Page 7: ...HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of GINJ 0201 BT 12 Series W x H x D is 30mm x 95mm x 75mm Figure 2 1 Physical Dimensions...

Page 8: ...3 below shows the top panel of the GINJ 0201 BT 12 Series Industrial Gigabit BT PoE Injector that is equipped with one 2 pin terminal block for relay contact alarm and 4 pin terminal block connectors...

Page 9: ...oE output budget Key trigger event 3 PoE over current per port Key trigger event 4 Cable short per port Key trigger event 5 One of the channels in Dual PD fail Notice When the relay is triggered becau...

Page 10: ...ght Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45 Pin...

Page 11: ...tive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten the wire clamp screws to...

Page 12: ...ct is shown below in Figure 2 6 Figure 2 6 Fault Alarm Contact Grounding Note Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connecti...

Page 13: ...IN Rail is pre installed on the industrial Ethernet injector from the factory If the DIN Rail is not on the unit please see Figure 3 1 to learn how to install the DIN Rail on it Figure 3 1 The Rear Si...

Page 14: ...IN Rail bracket is installed on the rear side of the injector insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Figure 3 2 Insert the Injector on the DIN Rail Step 4 Lightly...

Page 15: ...al Ethernet injector Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet injector Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 16: ...ing Installation section Step 4 Power on the industrial Injector and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Ple...

Page 17: ...t me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agit...

Page 18: ...t turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Leonton for tech...

Reviews: