14 

Trouble Shooting 

 
● 

Verify you have the right power cord or adapter. Never use a power supply or adapter with a 

non-compliant DC output voltage or it will burn the equipment.

 

 
● 

Select the proper UTP or STP cable in order to construct the network. Use an unshielded twisted-

pair  (UTP)  or  shield  twisted-pair  (STP)  cable  for  RJ-

45  connections:  100Ω  Category  5e  for 

10M/100/1000Mbps.  Also  be  sure  that  the  length  of  any  twisted-pair  connection  does  not 

exceed 100 meters (328 feet).

 

 
● 

Diagnosing LED Indicators: To assist in identifying problems, the switch can be easily monitored 

with the LED indicators which help to identity if any problems exist.

 

 

Please refer to the LED Indicators section for LED light indication.

 

 
● 

If the power indicator LED does not turn on when the power cord is plugged in, the user may 

have a problem with the power cord. Check for loose power connections, power losses or surges 

at the power outlet.

 

 

Please  contact  Leonton  for  technical  support  service,  if  the  problem  still  cannot  be 

resolved.

 

 
● 

If the industrial switch LED indicators are normal and the connected cables are correct but the 

packets still cannot transmit, please check the system’s Ethernet devices’ configuration or status.

 

For any repair or maintenance needs, please contact us. 

LEONTON TECHNOLOGIES, CO., LTD 

9F-1, No.43, Fuxing Rd., Xindian Dist.,  

New Taipei City, 231,  

Taiwan 

TEL: +886 2 22183113 

FAX: +886 2 22187391 

Summary of Contents for ET2-1600 Series

Page 1: ...LEONTON ET2 1600 Series ET2 1600 ET2 1600 T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...ee of this device could void the user s authority to operate the equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques conform...

Page 4: ...to take adequate measures CE Mark AVERTISSEMENT Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is the curre...

Page 5: ...Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Grounding Note 8 Mounting Installation 9 DIN Rail...

Page 6: ...t any needs for industrial automation application and harsh environments Key Features Interface Performance All Copper ports support auto MDI MDI X function Embedded 16 10 100Tx Ethernet Store and for...

Page 7: ...tection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convertisseur de...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of ET2 1600 series W x H x D is 46mm x 142mm x 99mm Figure 2 1 Physical Dimensions...

Page 9: ...2 2 Figure 2 2 The Front Panel Top View Figure 2 3 below shows the top panel of the ET2 1600 series switches that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 1...

Page 10: ...ption P1 Green On Power input 1 is active Off Power input 1 is inactive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...on Step 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten...

Page 13: ...1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit tre compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation jumelez...

Page 14: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 15: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 16: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 17: ...the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power In...

Page 18: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 19: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...

Reviews: