Cabling
Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The cable
between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100
meters (328 ft.) long.
Wiring the Power Inputs
Caution:
Please follow the below steps to insert the power wire.
Attention:
Veuillez suivre les étapes ci-dessous pour insérer le câble d'alimentation.
Step 1.
Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.4.
Figure 2.4: Power Terminal Block
Step 2.
Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.5.
Figure 2.5: Power Terminal Block
Caution:
Only use copper conductors. The rating of the power wire used must be at least
125°C, tighten to 7 in-lbs (0.79 Nm).
Attention:
N'utilisez que des conducteurs en cuivre. Le calibre du câble d'alimentation
utilisé doit être d'au moins 125 ° C, serrez à 7 in-lbs (0,79 Nm).