![Lenze Smart Motor m300 Mounting Instructions Download Page 31](http://html.mh-extra.com/html/lenze/smart-motor-m300/smart-motor-m300_mounting-instructions_1882462031.webp)
Technical data
General data and operating conditions
EN
31
Lenze ¯ MDKSEMA ¯ 5.0
Supply conditions
Mains connection
Power system
TT, TN
(with an earthed neutral)
Operation permitted without restrictions
Delta system
(outer conductor−earthed)
Operation not permissible.
IT system
Operation not permissible.
Voltage deviations
Voltage dips
EN 61800−3
Short−time mains voltage dips (cf. IEC 61000−2−1) may cause disconnection.
Control connections
Supply
24 V DC (19.2 ... 28.8 V) by safely separated power supply unit (SELV/PELV)
Digital inputs
IEC 61131−2, type 1
24 V DC, input resistance 5.6 k
W
Digital output
IEC 61131−2, type 1
24 V DC, max. 50 mA
Ambient conditions
Climatic
Transport
IEC/EN 60721−3−2
2K3 (−30 °C ... +70 °C)
Storage
IEC/EN 60721−3−1
1K3 (−30 °C ... +60 °C)
< 3 months
1K3 (−30 °C ... +40 °C)
> 3 months
Operation
IEC/EN 60721−3−3
3K3 (−10 °C ... +40 °C)
3K3 (−30 °C ... −10 °C)
Variant for deep−freeze applications
If combined with a gearbox:
The gearbox must also be suitable for the
temperature range.
Site altitude
< 1000 m amsl
Without power reduction
> 1000 m amsl < 4000m
amsl
With power reduction 5 %/1000 m
Permissible pollution
EN 61800−5−1
2
Mechanical
Vibration resistance
Transport
IEC/EN 60721−3−2
2M2
Operation
IEC/EN 60721−3−3
3M4
Vibrational severity
EN 60034−14
A
EMC
Interference emission
In TN and TT systems
Cable−guided
EN 61800−3
Category C2
Radiation
EN 61800−3
Category C2
Noise immunity
EN 61800−3
Requirements for industrial environments are complied with
Operation on public supply
systems
EN 61000−3−2
EN 61000−3−12
The devices are designed for the use in industrial environments. If they are used
on public systems, measures to reduce the expected emission of radio
interferences are to be implemented. The machine/system manufacturer is
responsible for compliance with the requirements for the machine/system!