Product description
Connections and interfaces
EN
29
Lenze ¯ MDKSEMA ¯ 5.0
2.2
Connections and interfaces
Note!
You only have to open the cover of the Lenze Smart motor if you connect
an external brake resistor or if you implement the mains connection
without a QUICKON connector.
1.7 Nm
(15 lb-in)
PE
X1
X2
X5
X3
X4
1.7 Nm
(15 lb-in)
MSEMA_001
X1, X2
Control connections, M12 connectors, A−coded, pins
X3
Mains connection, QUICKON connector or M25 x 1.5 cable gland
X4
Connection of external brake resistor, M12 x 1.5 cable gland
X5
Connection of spring−applied brake (pre−wired at delivery)
PE
Connection of second PE conductor