Error messages
13.2
Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PROFINET: Invalid IP parameters [0x00c86533]
PROFINET: Safety communication timeout [0x00c86610]
PROFINET: Safety parameter timeout [0x00c86611]
PROFINET: Safety init error [0x00c86612]
PROFINET: Safety connect error [0x00c86613]
PROFINET: Internal error [0x00c86650]
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Incorrect IP parameters (IP address, subnet mask,
gateway address).
Correct IP parameters.
Setting the IP configuration (
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Communication to the SM30x safety module is
disrupted.
Check if the SM30x safety module is plugged in and
supplied with voltage.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
The SM30x safety module does not respond to a
PROFISafe parameterisation frame within a given time
interval (200 ms).
Check if the SM30x safety module is plugged in and
supplied with voltage.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Communication to the SM30x safety module could not
be initialised correctly.
Check whether the user data length configured in the
PROFINET IO controller for the PROFIsafe data matches
the SM30x safety module used.
Configuring the PROFINET IO controller (
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Communication to the I/O controller is disrupted.
Check if the SM30x safety module is plugged in and
supplied with voltage.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Internal error
Send communication module together with a