Parameter reference
10.2
Parameters of the communication module for slot MXI1
78
Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13225
C13229
C13231
Parameter | Name:
C13225 | EPL MN: Max. user data RPDO
Data type: UNSIGNED_16
Index: 11350 = 0x2C56
EPL index: See subcodes
The code defines the reserved user data length of the PRes frames. Each subcode number corresponds to an EPL
node with the same node ID.
The subcode describes the PRes frames received. The value must be within the limits of 36 ... 1490 bytes.
The values are upper limit values for the total size of the PDO mappings which must be defined each one of the
codes
for PRes frames received.
In the configured state, the values stored for the EPL nodes must be identical to the corresponding
must have an identical value in all EPL nodes of the network.
Setting range
(min. value | unit | max. value)
0
Byte
1490
Subcodes
Lenze setting
Info
EPL index
C13225/1
0 byte
Managing node
0x1F8D.0xF0
C13225/2
0 byte
Diagnostics device
0x1F8D.0xFD
C13225/3
0 byte
router
0x1F8D.0xFE
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13229 | EPL multi-stage node declaration MN
Data type: UNSIGNED_8
Index: 11346 = 0x2C52
EPL index: See subcodes
This code indicates in which multiplexed cycle the node is queried. The value entered must not exceed the value in
If, for instance, the value "3" is entered in code
, the multiplexed cycle is repeated every three cycles. If now
the value "3" is entered for one node in C13229/x, it is always queried only in the second cycle of the three
multiplexed cycles.
Setting range
(min. value | unit | max. value)
0
Cycles
255
Subcodes
Lenze setting
Info
EPL index
C13229/1
0 cycles
Managing node
0x1F9B.0xF0
C13229/2
0 cycles
Diagnostics device
0x1F9B.0xFD
C13229/3
0 cycles
router
0x1F9B.0xFE
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13231 | EPL RPDO
Data type: UNSIGNED_64
Index: 11344 = 0x2C50
EPL index: See subcodes
EPL RPDO-1
Subcodes
Lenze setting
Info
EPL index
C13231/1
0
EPL RPDO
0x1600.0x01
...
...
...
...
C13231/32
0
EPL RPDO
0x1600.0x20
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT