Fuse data (F1 ... F3)
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Cable installation in compli-
ance with
EN 60204-1
Installation method
B2
Fuse
Characteristics
gG/gL
Typ. rated current
A
6
10
Max. rated current
A
16
16
Semiconductor fuse
Characteristics
gRL
Typ. rated current
A
6
10
Max. rated current
A
16
16
Circuit breaker
Characteristics
C
Typ. rated current
6
10
Max. rated current
A
16
16
•
Use of copper cables insulated with PVC
•
Conductor temperature < 70 °C, ambient temperature < 40 °C
•
No bundling of cables or wires, thee wires under load
Connection for group drive according to EN 60204-1
L1
L2
L3
N
PE
F1 … F3
K
M
3~
+
A
1
I
N1
PE L1 L2 L3
M
3~
+
A
2
I
N2
PE L1 L2 L3
M
3~
+
A
3
I
N3
PE L1 L2 L3
M
3~
+
A
4
I
N4
PE L1 L2 L3
M
3~
+
A
n
I
Nn
PE L1 L2 L3
Max. total rated mains currents at 40 °C
Cable installation in compli-
ance with
EN 60204-1
Laying system
B2
cable cross‐section
mm
2
1.5
2.5
(I
N1
+ L
N2
+ I
N3
+ I
Nn
) x 80% A
7.6
12.2
Fuse
Characteristics
gG/gL
Typ. rated current
A
---
---
Max. rated current
A
10
16
Circuit breaker
Characteristics
gRL
Typ. rated current
A
---
---
Max. rated current
A
10
16
•
Use of copper cables insulated with PVC
•
Conductor temperature < 70 °C, ambient temperature < 40 °C
•
No bundling of cables or wires, thee wires under load
Electrical installation
Mains connection
Connection according to EN
62