Maintenance/repair
Maintenance operations
Checking the rotor thickness
47
Lenze ¯ BA 33.0008 ¯ 5.0
Check the mounting dimension of the manual release
(
Stop!
Dimension "s" must be maintained! Check air gap "s
L
"!
(
^
operating instructions)
Size
s
L
(mm)
s
+0.1
(mm)
s + s
L
(mm)
06
0.2
1
1.2
08
10
12
0.3
1.5
1.8
14
16
18
0.4
2
2.4
20
25
0.5
2.5
3
8.3.4
Checking the rotor thickness
}
Danger!
When the rotor thickness is checked, the motor must not run.
1. Remove fan cover and cover ring if attached.
2. Measure rotor thickness with calliper gauge. If a friction plate is attached, ensure
a flanged edge at the outer diameter of the friction plate.
3. Compare measured rotor thickness with minimally permissible rotor thickness
(values
^
4. If required, exchange the entire rotor. Description
^
8.3.5
Checking the air gap
1. Check the air gap "s
L
" near the fixing screws between the armature plate and
stator using a feeler gauge (
^
2. Compare air gap measured to maximally permissible air gap "s
L max.
" (
^
3. If required, set air gap to "s
LN
" (
^