Mechanical installation
Mounting
Preparation
l
21
BA 12.0023−EN 6.0
4.4
Mounting
4.4.1
Preparation
(
Stop!
Thoroughly remove anticorrosion agents from output shafts and flange faces.
Correcting the oil quantity
If the oil quantity has been increased in the gearbox for long−term storage (see chapter
4.2), the oil must be completely drained and then filled in again for the corresponding
mounting position. The following steps must be observed:
1. Place receptacle under oil drain plug.
2. Remove ventilation / oil filler plug.
3. Completely drain lubricant.
4. Screw in oil drain plug.
5. Fill in oil quantity for the corresponding mounting position (see chapter 7.2.5).
6. Screw in ventilation / oil filler plug.
Condensation drain hole
)
Note!
Lenze delivers motors with condensation drain holes with sealed condensation
drain holes. The holes are sealed with a plastic plug or a plug screw. This does
not impair the enclosure and the motor is protected against ingress of foreign
particles during transport and operation. For further information, please see
chapter 7.2.1.