Lenze−Codestellen und CANopen−Objekte
Description of the codes relevant for the modem
l
64
EDSMF2181IB EN 3.0
C1225:
baud rate of the external modem
Code
C1225
Name
Baud rate of the external modem
Index: 0x5B36 (23350)
Subcode
Lenze
Values
Access
Data type
3
0
9600 bps
rw
FIX32
1
19200 bps
2
38400 bps
3
57600 bps
¨
RSP
þ
PS transfer
¨
CANopen:
Code C1225 is used for determining the baud rate via which the communication module
communicates with external modems. Most modems are provided with a function for the
automatic detection of the baud rate, so that it is not necessary to alter this parameter.
Only in exceptional cases, the default baud rate of the external modem must be set here.
If initialisation with the baud rate configured fails, an automatic attempt to use another
baud rate is made.
)
Note!
Changes to this code only become effective if the mains is switched again, or
by a modem reset (code C1226).
C1226:
modem reset
Code
C1226
Name
Modem reset
Index: 0x5B35 (23349)
Subcode
Lenze
Values
Access
Data type
0
0, 1
rw
I32
¨
RSP
þ
PS transfer
¨
CANopen:
The change made to the modem parameters only becomes effective when the mains is
switched for the next time, or by activation of code C1226.