Technical data
General data and operating conditions
4
l
15
EDSMF2181IB EN 3.0
4
Technical data
4.1
General data and operating conditions
Range
Values
Order designation
EMF2181IB
Communication media (system)
CAN (DIN ISO 11898)
Lenze diagnostic interface
Communication media (external)
Telephone analogue, 33.6 kbit/s, (V34)
Number of nodes at the CAN bus
Max. 100
Baud rate
l
when communicating via CAN
– 20 kbit/s
– 50 kbit/s
– 125 kbit/s
– 250 kbit/s
– 500 kbit/s
– 1000kbit/s
l
For communication via diagnostic interface
– 230.4 kbit/s
Voltage supply (external) via
separate power supply
18 30 V DC, max. 100 mA (in accordance with EN 61131−2)
Conformity and approval
Conformity
CE
2004/108/EC
EMC Directive
EAC
TP TC 020/2011
(TR CU 020/2011)
Electromagnetic
compatibility of technical
means
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
EAC
TP TC 004/2011
(TR CU 004/2011)
On safety of low voltage
equipment
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Operating conditions
Values
Deviations from the standard
Climatic conditions
Storage 1 K3 to IEC/EN 60721−3−1
− 10 ... + 60 °C
Transport 2 K3 acc. to IEC/EN 60721−3−2
− 10 ... + 70 °C
Operation 3 K3 acc. to IEC/EN 60721−3−3
0 ... + 60 °C
Enclosure of attached module
IP20
Degree of pollution
2 acc. to IEC/EN 61800−5−1