7.9.3
Position correction
The correction window specifies the position range. The tool position is corrected within the
position range. The position of the correction window is specified via the parameters Tool
lower correction position and Tool upper correction position.
•
Tool lower correction position
•
Tool upper correction position
The parameters are set in the unit of the tool axis.
The Tool sensor distance parameter specifies the distance between the touch probe sensor
and the zero position of the tool on the material.
Sensor
Slave
LowerCorrPos
UpperCorrPos
Correction range
Reference position
Fig. 62: Homing on the fly without mark stack
Parameter
Address
Name / setting range / [default setting]
Info
0x5041:121
Tool sensor distance
0.0000 ... [360.0000] ... 214748.3647
0x5041:122
Max. positive tool correction
0.0000 ... [45.0000] ... 214748.3647
0x5041:123
Max. negative tool correction
0.0000 ... [45.0000] ... 214748.3647
0x5041:124
Tool upper correction position
0.0000 ... [350.0000] ... 214748.3647
0x5041:125
Tool lower correction position
0.0000 ... [180.0000] ... 214748.3647
0x5041:130
Activate tool correction
false Deactivated
true Activated
0x5042:141
Actual position tool correction mark
•
Read only
0x5042:142
Actual tool error
•
Read only