Parameter
Address
Name / setting range / [default setting]
Info
0x5040:023
External position offset
-214748.3648 ... [0.0000] ... 214748.3647
0x5041:022
Offset direction allowed
0 Both directions
1 Master value direction
0x5041:024
Trimming - position difference
0.0000 ... [1.0000] ... 214748.3647
0x5041:025
Trimming - velocity
-214748.3648 ... [50.0000] ... 214748.3647
0x5041:026
Trimming - acceleration
-21474836.48 ... [100.00] ... 21474836.47
0x5041:027
Trimming - deceleration
-21474836.48 ... [100.00] ... 21474836.47
0x5041:028
Jerk offset
-21474836.48 ... [10000.00] ... 21474836.47
0x5041:053
Internal position offset
-214748.3648 ... [0.0000] ... 214748.3647
0x5041:058
Load offset
false
true
0x5042:021
Set velocity after measuring system alignment
•
Read only
0x5042:025
Active position offset
•
Read only
0x5042:026
Velocity offset
•
Read only
0x5042:027
Trimming position offset
•
Read only
0x5042:028
Trimming - velocity offset
•
Read only
0x5042:029
Total position offset
•
Read only
0x5042:030
Total velocity offset
•
Read only
7.5
Position offset from master
Relevant parameters of other functions
Address
Designation
Default setting
Setting range
External position offset
0.0000
-214748.3648 ... 214748.3647
Offset direction allowed
Master value direction [1]
Selection list
Trimming - velocity
50.0000
-214748.3648 ... 214748.3647
Trimming - acceleration
100.00
-21474836.48 ... 21474836.47
Trimming - deceleration
100.00
-21474836.48 ... 21474836.47
Jerk offset
10000.00
-21474836.48 ... 21474836.47
Internal position offset
0.0000
-214748.3648 ... 214748.3647
Load offset
0
Configuring the "Sync and Correction" TA
Position offset from master
120