Safety instructions
Residual hazards
10
Lenze ¯ MA 12.0018 ¯ 2.0
2.4
Residual hazards
Protection of persons
¯
Risk of burns!
–
Hot surfaces up to 140 °C during operation! Provide protection against contact.
¯
High−frequency voltages can be capacitively transferred to the motor housing
through the inverter supply.
–
Earth motor housing carefully.
¯
Risk of injury due to rotating shaft!
–
Before working on the motor ensure that the motor is at standstill.
¯
Danger of unintentional starting or electrical shocks!
–
Connections must only be made when the equipment is deenergised and the
motor is at standstill.
–
Installed brakes are no fail−safe brakes.
¯
Dangerous voltages at the power terminals, even if the plug is removed: residual
voltage >60 V!
Motor protection
¯
Installed thermal detectors do
not offer full protection
to the machine.
–
If required, limit the maximum current, parameterise the inverter so that it will
be switched off after some seconds of operation with I > I
N
, especially if there is
the danger of blocking.
–
Installed overload protection does not prevent an overload under any
conditions.
¯
Installed brakes are
no fail−safe brakes
.
–
The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.
¯
Fuses are no motor protection.
–
Use current−dependent motor protection switches at an average operating
frequency.
–
Use installed thermal detectors at a high operating frequency.
¯
Excessive torques lead to a break of the motor shaft or demagnetisation.
–
The maximum torques according to catalogue must not be exceeded.
¯
Lateral forces from the motor shaft may occur.
–
Align shafts of motor and driving machine exactly to each other.
¯
If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in
doubt, switch off the motor.
¯
Design with plug:
–
Never disconnect plug when energised! Otherwise, the plug can be destroyed.
–
Switch off power supply and inhibit controller prior to disconnecting the plug.