Function library
Function blocks
3.2.48
First order derivative−action element (DT1)
3−163
l
EDSVS9332K−EXT EN 4.0
3.2.48
First order derivative−action element (DT1)
Purpose
Derivative action on signals.
For instance, used for the acceleration processes (dv/dt).
DT1-1
DT1-1-OUT
DT1-1-IN
C0654
C0651
C0652
±199.99 %
C0653
C0650
fb_dt1−1
Fig. 3−125
First order derivative−action element (DT1−1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DT1−1−IN
a
C0654
dec [%]
C0652
1
1000
−
DT1−1−OUT
a
−
−
−
−
−
Limited to ±199.99 %
Function
l
The gain is set under C0650.
l
The delay T
v
is set under C0651.
l
The input sensitivity of the DT1−1 element can be reduced under C0653.
l
The FB only evaluates the specified most significant bits, according to the setting.
t
T
v
K=T
d
/ T
v
Fig. 3−126
Delay time T
v
of the first order derivative−action element
Summary of Contents for EVS93 Series
Page 2: ......
Page 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Page 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Page 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Page 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Page 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Page 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Page 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Page 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Page 385: ......