Technical data
Electrical data
Interface description
61
EDBPM−H505 DE/EN/FR 6.1
2.2.2
Interface description
Note!
ƒ
The EPM−H505 operating unit is equipped with the serial
interface MSP.
ƒ
The EPM−H507 operating unit is equipped with the serial
interface ASP8.
MSP
ASP8
1
14
1
2
3
4
5
6
7
8
h410_013
h310_010
Fig. 2−1
MSP DB25 socket and ASP8 Minidin 8 pole socket
Pin
Signal
Pin
Signal
1
n.c.
1
Rx RS232 IN
2
Tx RS232 OUT
2
Tx RS232 OUT
3
Rx RS232 IN
3
n.c.
4
RTS RS232 OUT
4
RTS RS232 OUT
5
CTS RS232 IN
5
CTS RS232 IN
6
n.c.
6
n.c.
7
Signal GND
7
Signal GND
8
n.c.
8
+5 VCC (reserved)
9 ... 16
Signals are not evaluated
17
n.c.
18
Signal is not evaluated
19 ... 21
n.c.
22 ... 25
Signals are not evaluated
n.c.
Not connected