Electrical installation
Power terminals
53
EDBCSXS064 EN 4.0
ƒ
All power connections are plug connections and coded. The ECSZA000X0B plug
connector set must be ordered separately.
ƒ
Installation of the cables to EN 60204−1.
ƒ
The cables used must comply with the approvals required at the site of use (e.g. VDE,
UL, etc.).
Note!
ECSDS...
axis modules:
For a better electromagnetic compatibility (EMC), connect the functional earth
conductor to the ECS
D
S... axis module (
This is not required for the ECS
E
S... (standard installation) and ECS
C
S... (cold
plate) axis modules!
Assignment of the plug connectors
Plug
connector/terminal
Function
Electrical data
X23
DC−bus voltage connection
X23/+UG
Positive DC−bus voltage
Dependent on application and type
0 ... 770 V
2 ... 24.5 A (
X23/+UG
X23/−UG
Negative DC−bus voltage
X23/−UG
X23/PE
Earth connection
X23/PE
X24
Motor connection
X24/U
Motor phase U
Dependent on application and type
0 ... 480 V
1.6 ... 20 A (
X24/V
Motor phase V
X24/W
Motor phase W
X24/PE
Earth connection
X25
Motor holding brake connection
X25/BD1
Brake conn
23 ... 30 V DC,
max. 1.5 A
X25/BD2
Brake connection −
Cable cross−sections and screw−tightening torques
Cable type
Wire end ferrule
Possible cable
cross−sections
Tightening torque
Stripping length
Plug connectors X23 and X24
Rigid
˘
0.2 ... 10 mm
2
(AWG 24 ... 8)
1.2 ... 1.5 Nm
(10.6 ... 13.3 lb−in)
5 mm for screw
connections
10 mm for spring
connections
Flexible
Without wire end
ferrule
0.2 ... 10 mm
2
(AWG 24 ... 8)
Insulated with wire
end ferrule
0.25 ... 6 mm
2
(AWG 22 ... 10)
Insulated with wire
end ferrule
0.25 ... 4 mm
2
(AWG 22 ... 12)
Plug connector X25
Flexible
Insulated with wire
end ferrule
0.25 ... 2.5 mm
2
(AWG 22 ... 12)
0.5 ... 0.8 Nm
(4.4 ... 7.1 lb−in)
5 mm for screw
connections
10 mm for spring
connections
Without wire end
ferrule
0.2 ... 2.5 mm
2
(AWG 24 ... 12)