Technical data
Rated data
33
EDBCSXS064 EN 4.0
3.2
Rated data
Rated data
Type
Axis module
ECSx
004
ECSx
008
ECSx
016
Output power 400 V mains
S
rated
[kVA]
1.3
2.6
5.3
Data for operation with upstream power supply module
on mains voltage
V
mains
[V]
400
480
400
480
400
480
DC−bus voltage
V
DC−bus
[V]
15 ... 770
DC−bus current
I
DC−bus
[A]
2.5
2.0
4.9
3.9
9.8
7.8
Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an ambient
temperature of 20°C)
I
r
[A]
2.0
1.6
4.0
3.2
8.0
6.4
Rated output current at 8 kHz
(at an ambient
temperature of 20°C it causes a heatsink temperature
of 70°C)
1)
I
r
[A]
1.4
1.1
2.7
2.2
5.3
4.2
Max. output current
(acceleration current)
I
max
[A]
4.0
8.0
16.0
Continuous current at standstill
(holding current at 90°C, 4 kHz)
I
0,eff 4 kHz
[A]
2.0
1.6
4.0
3.2
8.0
6.4
Short−time standstill current
(holding current at 90 °C, 4 kHz)
2)
I
0,eff 4 kHz
[A]
2.3
4.6
9.1
Short−time standstill current
(holding current at 70 °C, 4 kHz)
2)
I
0,eff 4 kHz
[A]
3.0
6.0
12.0
Short−time standstill current
(holding current at 70 °C, 8 kHz)
2)
I
0,eff 8 kHz
[A]
1.5
3.0
6.0
Power loss (operation with rated
current at 4 kHz / 8 kHz)
Total
P
loss
[W]
27.3
46.3
84.7
Inside the device
13.3
17.3
20.7
Heatsink
14.0
29.0
64.0
Max. output frequency
f
out
[Hz]
600
Mass
m [kg]
approx. 2.4
1)
If the heatsink temperature reaches 70°C, the switching frequency automatically changes to 4 kHz.
2)
The indicated temperature is the measured heatsink temperature (C0061).
Application software:
S = Speed & Torque
P = Posi & Shaft
M = Motion
A = Application