Function library
AIF2In
257
EDBCSXS064 EN 4.0
User data
Each of the eight bytes of received user data is assigned to different signal types. For this
reason, they can be evaluated —as required— as
ƒ
digital signals (1 bit)
ƒ
analog signals (16 bit)
ƒ
phase signals (32 Bit)
in the axis module:
Byte
Digital signals (1 bit)
Analog signals (16 Bit)
Phase signals (32 Bit)
1, 2
AIF2In−Bit0
...
AIF2In−Bit15
AIF2In−W0
AIF2In−W0/W1
3, 4
AIF2In−Bit16
...
AIF2In−Bit31
AIF2In−W1
5, 6
AIF2In−W2
AIF2In−W2/W3
7, 8
AIF2In−W3