Lenze · E84AYCEC communication module (POWERLINK) · EDS84AYCEC EN 4.0 - 02/2019
75
Parameter reference
Parameters of the communication module
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13859
C13860
C13861
Parameter | Name:
C13859 | 0x1A00.0 Number of mapped Tx PDO-1
Data type: UNSIGNED_8
Index: 10716
d
= 29DC
h
Number of sent PDOs via the PDO channel 1 (Tx)
Display range
(min. value | unit | max. value)
0
16
Subcodes
Info
C13859/1
0x1A00.0 Number of mapped Tx PDO-1
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13860 | 0x160x.0 Number of mapped Rx PDO
Data type: UNSIGNED_8
Index: 10715
d
= 29DB
h
Number of received PDOs via PDO channels 1 ... 6 (Rx)
Display range
(min. value | unit | max. value)
0
16
Subcodes
Info
C13860/1
0x1600.0 Number of mapped Rx PDO-1
...
...
C13860/6
0x1605.0 Number of mapped Rx PDO-6
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13861 | 0x1F8C NMT Communication Status
Data type: UNSIGNED_8
Index: 10714
d
= 29DA
h
The code displays the current NMT state (according to the Ethernet POWERLINK specification) of the EPL node.
Selection list
(read only)
Info
0 Off
NMT_GS_OFF
25 Initialising
NMT_GS_INITIALISING
41 ResetAppl
NMT_GS_RESET_APPLICATION
57 ResetComm
NMT_GS_RESET_CONFIGURATION
121 ResetConfig
NMT_GS_RESET_CONFIGURATION
28 NotActive
NMT_CS_NOT_ACTIVE
29 PreOp1
NMT_CS_PRE_OPERATIONAL_2
93 PreOp2
NMT_CS_PRE_OPERATIONAL_2
109 ReadyToOp
NMT_CS_READY_TO_OPERATE
253 Operational
NMT_CS_OPERATIONAL
77 Stopped
NMT_CS_STOPPED
30 BasicEthernet
NMT_CS_BASIC_ETHERNET
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM