Lenze · E84AYCEC communication module (POWERLINK) · EDS84AYCEC EN 4.0 - 02/2019
65
Parameter reference
Parameters of the communication module
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11
Parameter reference
[ALinkKeywords]
Parameters
This chapter supplements the parameter list and the table of attributes for the Inverter Drive 8400
contained in the software manual and in the »Engineer« online help by the parameters of the com-
munication module E84AYCEC (POWERLINK).
[Search-Keywords]
Hlp_Para
11.1
Parameters of the communication module
This chapter lists the parameters of the E84AYCEC communication module (POWERLINK) in nume-
rically ascending order.
C13000
C13001
Software manual/»Engineer« online help for Inverter Drive 8400
Here you will find general information on parameters.
Parameter | Name:
C13000 | 0x1E40.2 IP Address
Data type: UNSIGNED_32
Index: 11575
d
= 2D37
h
The code displays the IP address of the communication module.
• The IP address is derived from the EPL node address (Node ID):
192.168.100.[Node ID]
• The node ID is derived from the coding switch position or from
Display range
(min. value | unit | max. value)
0.0.0.0
(0x00000000)
255.255.255.255
(0xFFFFFFFF)
Subcodes
Info
C13000/1
IP address
• Lenze setting: 0xC0A86401 = 192.168.100.1
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13001 | 0x1E40.3 Subnet Mask
Data type: UNSIGNED_32
Index: 11574
d
= 2D36
h
The code declares the IP subnet mask which restricts the directly addressable IP address range (i.e. without a gate-
way in the EPL segment of the routers). The value 255.255.255.0 (0xFFFFFF00) is always assigned to the subnet mask
in one segment.
Display range
(min. value | unit | max. value)
255.0.0.0
(0xFF000000)
255.255.255.0
(0xFFFFFF00)
Subcodes
Info
C13001/1
EPL IP Subnet Mask
• Lenze setting: 0xFFFFFF00 = 255.255.255.0
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT