Electrical installation
Connecting the supply voltage
l
µ
79
EDBPM−H605 DE/EN/FR 6.0
5.2
Connecting the supply voltage
(
Stop!
Damage to connected devices. Connect the PE conductor as shown
in the illustration!
~
PE
PE
N
L1
DC +18…32V
DC + 24 V
DC + 24 V
DC + 24 V
DC + 24 V
DC 0 V
DC 0 V
DC 0 V
DC 0 V
GNYE
RD
BK
21
C1
22
C2
EPM-H606 (HW 1A, 1B)
EPM-H606 (HW 1D)
EPM-H605
h605_007
Fig.5−1
Connect the supply voltage
EPM−H605
Operating unit for fixed connection
EPM−H606 (HW 1A, 1B)
Operating unit with 42−pole plug (hardware versions 1A and
1B)
EPM−H606 (HW 1D)