3-phase mains connection 230/240 V
Rated data
The inverters I51AExxxC and I51AExxxD do not have an integrated RFI filter in the AC mains supply.
In order to meet the EMC requirements according to EN 61800−3, an external EMC filter according
to IEC EN 60939 must be used.
The user must verify that the conformity with EN 61800−3 is fulfilled.
The output currents apply to these operating conditions:
•
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45 °C.
•
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter
I51AE
125D
137D
155D
175D
211D
215D
222D
240C
255C
Rated power
P
rated
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
4
5.5
Rated power
P
rated
hp
0.33
0.5
0.75
1
1.5
2
3
5
7.5
Mains voltage range
3/PE AC 195 V ... 264 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0 - 230/240 V
Rated mains current
without mains choke
A
2.6
3.9
4.8
6.4
7.8
9.5
13.6
20.6
28.8
with mains choke
A
2
3
3.8
5.1
5.6
6.8
9.8
15.7
21.9
Apparent output power
kVA
0.6
0.9
1.2
1.6
2.2
2.6
3.6
6.4
8.7
Rated output current
2 kHz
A
-
3.2
4.2
6
7
9.6
16.5
23
4 kHz
A
1.7
2.4
3.2
4.2
6
7
9.6
16.5
23
8 kHz
A
1.7
2.4
3.2
4.2
6
7
9.6
16.5
23
16 kHz
A
1.1
1.6
2.1
2.8
4
4.7
6.4
11
15.3
Power loss
2 kHz
W
-
22
27
36
41
54
113
166
4 kHz
W
15
18
23
29
37
43
60
115
175
8 kHz
W
15
20
25
33
42
50
70
130
195
16 kHz
W
19
24
30
38
51
59
78
116
159
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
-
Min. brake resistance
-
Max. motor cable length
shielded
without EMC category
m
50
Category C1 (2 kHz, 4 kHz,
8 kHz)
m
-
Category C2 (2 kHz, 4 kHz,
8 kHz)
m
-
Category C3 (2 kHz, 4 kHz,
8 kHz)
m
-
Max. motor cable length
unshielded
without EMC category
m
-
Technical data
3-phase mains connection 230/240 V
Rated data