7.3 Reset
If you have recurring problems when operating or registering an
LH101-R, we recommend resetting the LH101-R and LTM101.
7.3.1 Reset of the LH101-R
The radio module of the handset control LH101-R resets itself when
you switch on the handset control with the M button pressed. The
LH101-R then deletes the existing connection to an LTM101 receiver.
The LH101-R must then be re-registered with an LTM101 receiver.
This is described in the section "Register another LH101-R" starting
on page 31.
7.3.2 Reset of the LTM101
Switch off all LH101-R radio handheld controllers registered to this
LTM101.
Disconnect the LTM101 from the XpressNet.
Open the housing of the LTM101 with the tabs on the side. Inside you
will find a red dip switch block on the circuit board. Make a note of the
current position of the DIP switches. Then set all dip switches to 'ON'.
Now press and hold the button on the LTM101 receiver while
reconnecting the receiver to the XpressNet. The LED will flash rapidly
after a few seconds.
Now disconnect the LTM101 from the XpressNet.
Set the dip switches back to their original position and reconnect the
LTM101 to the XpressNet.
Now all logins stored in the LTM101 are deleted, the LTM101 is in
"search for LH101-R" mode. Now LH101-R can be registered again.