Silver Locomotive decoder
9
30
Fault indication
0 (dec)
bit 0 (1)
= 1 Light short-circuit
0,1 [1]
0
bit 1 (2)
= 1 Overheating
0,1 [2]
0
bit 2 (3)
= 1 Motor short-circuit
0,1 [4]
0
CV
33
–
46
Function mapping for function outputs:
In order to allocate a function of the digital system to a function
output, look for the section where the row of the desired function
meets the column of the desired function output. Enter the number
found in the respective CV. For the purpose of clarification, factory
settings are shown in bold print.
Factory
setting
CV
Function
output:
A
B
C
D
33
F0 forward
8
16
32
64
8
34
F0 backward
8
16
32
64
16
35
Function 1
8
16
32
64
32
36
Function 2
8
16
32
64
64
37
Function 3
8
16
32
64
128 (*)
38
Function 4
1
2
4
8
32 (*)
39
Function 5
1
2
4
8
64 (*)
40
Function 6
1
2
4
8
128 (*)
41
Function 7
1
2
4
8
0
42
Function 8
1
2
4
8
0
43
Function 9
1
0
44
Function 10
1
0
45
Function 11
1
0
46
Function 12
This range does not allow
mapping of functions
1
0
(*)-These values are not significant
for SILVER 10432 and 10433.
50
Motor configuration
0 (dec)
bits 0-3
(1-4)
Select motor type 0-5, enter as decimal number
0,1
[0-5]
0
Bit 5 (6) =0 EMF switch inactive
=1 EMF switch active
0,1
[32]
0
Bit 6 (7) =0 Control switched on
=1 Control switched off
0,1
[64]
0
Bit 7 (8) =0 High-frequency motor control (approx. 23 kHz)
=1 Low-frequency motor control (approx. 19 Hz)
0,1
[128]
0
51
Braking configuration
0 (dec)
bit 0 (1) = 1 Constant braking distance activated
0,1 [1]
0
bit 1 (2)) = 1 ABC activated
0,1 [2]
0
bit 2 (3) = 1 ABC direction-dependency deactivated
0,1 [4]
0
bit 3 (4) = 1 Activate push-pull operation without
intermediate stop
0,1 [8]
0
bit 4 (5) = 1 Activate push-pull operation with intermediate
stop
0,1 [16]
0
bit 5 (6) = 1 Stopping with DC independent of the polarity
(only if Bit 3 is deleted in CV29).
0,1 [32]
bits 6-7 (7-8)
Not used
0