42
YOGA 710-11ISK/YOGA 710-11IKB Hardware Maintenance Manual
1070 Thermal module
For access, remove these FRUs in order:
•
•
“1020 Battery pack” on page 35
Figure 7. Removal steps of thermal module
Loosen the screws
1
. Then remove the thermal module in the direction shown
by arrow
2
.
2 1
1
1
1
Attention:
Do not handle the heat sink assembly roughly. Improper handling
can cause distortion or deformation and imperfect contact with components.
a
When installing:
Before you attach the fan assembly to the computer, apply
thermal grease, at an amount of 0.2 grams, to the
a
part shown in the figure
above. Either too much or too less grease application can cause a thermal
problem due to imperfect contact with a component.