© Copyright Lenovo 2019
Chapter 3: Installing NE1072T Hardware and Options
47
To install the NE1072T in an iDataPlex rack, complete the following steps:
1.
Locate, record, and retain the product switch information in order to configure and
register your product. See
“Before Installing the NE1072T” on page 34
.
Note:
If this switch is a replacement switch, copy the product information from the
original switch onto the RID label that is shipped with replacement switch and
affix the new label to the bottom of the new switch.
2.
Attach front mounting brackets (Item 1) and rear mounting brackets (Item 5) to
each side of the switch with M4 screws (Item 2). Torque the screws to
approximately 2 newton-meters (Nm) +/- 0.1 Nm (17.7 inch-pounds).
3.
From the front, slide the switch into the rack at the desired height.
4.
Secure the switch to the front rack posts with M6 screws (Item 3), and clip nuts
(Item 4). Torque the screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).
1
2
5
3
4
Summary of Contents for ThinkSystem NE1072T
Page 6: ...6 Lenovo NE1072T Installation Guide ...
Page 16: ...16 NE1072T Installation Guide ...
Page 56: ...56 NE1072T Installation Guide ...
Page 74: ...74 NE1072T Installation Guide ...
Page 90: ...90 NE1072T Installation Guide ...
Page 96: ...96 NE1072T Installation Guide ...
Page 112: ...112 NE1072T Installation Guide ...
Page 118: ...118 NE1072T Installation Guide ...