Diagnostic Error Code
FRU/Action
080-197-XXX
Game Port interface test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
080-198-XXX
Game Port interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Flash the system and re-test. See “Flash update
procedures” on page 285
3. Go to “Undetermined problems” on page 73
080-199-XXX
Game Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 73
2. Flash the system and re-test. See “Flash update
procedures” on page 285
3. Replace component under function test
086-000-XXX
Mouse Port interface Test Passed
No action
086-001-XXX
Mouse Port interface Presence
1.
Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller
failure
1.
Mouse
2. System board
086-035-XXX
Mouse Port interface Reset
1.
Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure
1.
Run Setup
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Test aborted by user
Information only
Re-start the test, if necessary
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
086-197-XXX
Mouse Port interface test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
086-198-XXX
Mouse Port interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Flash the system and re-test. See “Flash update
procedures” on page 285
3. Go to “Undetermined problems” on page 73
Chapter 9
.
Symptom-to-FRU Index
65
Summary of Contents for ThinkSTaTion series
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 8: ...vi ThinkStation Hardware Maintenance Manual ...
Page 17: ...Chapter 2 Safety information 9 ...
Page 21: ...Chapter 2 Safety information 13 ...
Page 22: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 23: ...Chapter 2 Safety information 15 ...
Page 29: ...Chapter 2 Safety information 21 ...
Page 33: ...Chapter 2 Safety information 25 ...
Page 40: ...32 ThinkStation Hardware Maintenance Manual ...
Page 58: ...50 ThinkStation Hardware Maintenance Manual ...
Page 82: ...74 ThinkStation Hardware Maintenance Manual ...
Page 95: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 126: ...118 ThinkStation Hardware Maintenance Manual ...
Page 223: ...Chapter 12 FRU lists 215 ...
Page 296: ...288 ThinkStation Hardware Maintenance Manual ...
Page 303: ......
Page 304: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...