Diagnostic Error Code
FRU/Action
011-196-XXX
Serial port test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
011-197-XXX
Serial port test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
011-198-XXX
Serial port test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Flash the system and re-test. See “Flash update
procedures” on page 285
3. Go to “Undetermined problems” on page 73
011-199-XXX
Serial port test failed, cause unknown
1. Go to “Undetermined problems” on page 73
2. Flash the system and re-test. See “Flash update
procedures” on page 285
3. Replace component under function test
011-2XX-XXX
Serial port signal failure
1.
External serial device
2. System board
014-000-XXX
Parallel port Interface Test Passed
No action
014-001-XXX
Parallel port Presence
1.
Remove external parallel device, if present
2. Run setup, enable port
3. System board
014-002-XXX 014-003-XXX
Parallel port Timeout/Parity
error
System board
014-013-XXX 014-014-XXX
Parallel port Control
Signal/Loopback test failure
System board
014-015-XXX
Parallel port External Loopback failure
1.
Wrap plug
2. System board
014-027-XXX
Parallel port Configuration/Setup error
1.
Run Setup, enable port
2. Flash the system. See “Flash update procedures”
on page 285
3. System board
014-03X-XXX 014-04X-XXX
Parallel port failure
System board
014-195-XXX
Parallel port Test aborted by user
Information only
Re-start the test, if necessary
014-196-XXX
Parallel port test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
58
ThinkStation Hardware Maintenance Manual
Summary of Contents for ThinkSTaTion series
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 8: ...vi ThinkStation Hardware Maintenance Manual ...
Page 17: ...Chapter 2 Safety information 9 ...
Page 21: ...Chapter 2 Safety information 13 ...
Page 22: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 23: ...Chapter 2 Safety information 15 ...
Page 29: ...Chapter 2 Safety information 21 ...
Page 33: ...Chapter 2 Safety information 25 ...
Page 40: ...32 ThinkStation Hardware Maintenance Manual ...
Page 58: ...50 ThinkStation Hardware Maintenance Manual ...
Page 82: ...74 ThinkStation Hardware Maintenance Manual ...
Page 95: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 126: ...118 ThinkStation Hardware Maintenance Manual ...
Page 223: ...Chapter 12 FRU lists 215 ...
Page 296: ...288 ThinkStation Hardware Maintenance Manual ...
Page 303: ......
Page 304: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...