Diagnostic Error Code
FRU/Action
011-196-XXX
Serial port test halt, error threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
011-197-XXX
Serial port test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
011-198-XXX
Serial port test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Flash the system and re-test. See “Updating
(flashing) the BIOS” on page 169.
3. Go to “Undetermined problems” on page 65.
011-199-XXX
Serial port test failed, cause unknown
1. Go to “Undetermined problems” on page 65.
2. Flash the system and re-test. See “Updating
(flashing) the BIOS” on page 169.
3. Replace component under function test.
011-2XX-XXX
Serial port signal failure
1. External serial device
2. System board
014-000-XXX
Parallel port Interface Test Passed
No action
014-001-XXX
Parallel port Presence
1. Remove external parallel device, if present.
2. Run the Setup Utility program, enable port
3. System board
014-002-XXX 014-003-XXX
Parallel port Timeout/Parity
error
System board
014-013-XXX 014-014-XXX
Parallel port Control
Signal/Loopback test failure
System board
014-015-XXX
Parallel port External Loopback failure
1. Wrap plug
2. System board
014-027-XXX
Parallel port Configuration/Setup error
1. Run the Setup Utility program, enable port
2. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
3. System board
014-03X-XXX 014-04X-XXX
Parallel port failure
System board
014-195-XXX
Parallel port Test aborted by user
Information only Restart the test, if necessary.
014-196-XXX
Parallel port test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
50
ThinkStation Hardware Maintenance Manual
Summary of Contents for THINKSTATION 7782
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Types 7782 7783 7821 7823 and 7824 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Types 7782 7783 7821 7823 and 7824 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 72: ...66 ThinkStation Hardware Maintenance Manual ...
Page 110: ...104 ThinkStation Hardware Maintenance Manual ...
Page 174: ...168 ThinkStation Hardware Maintenance Manual ...
Page 178: ...172 ThinkStation Hardware Maintenance Manual ...
Page 183: ......
Page 184: ...Part Number 0A74658 Printed in USA 1P P N 0A74658 0A74658 ...