Diagnostic Error Code
FRU/Action
000-197-XXX
BIOS test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Re-run test.
3. Replace the component that is called out in warning
statement
4. Replace the component under test.
000-198-XXX
BIOS test aborted
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Flash the system and retest. See “Updating
(flashing) the BIOS” on page 169.
3. Go to “Undetermined problems” on page 65.
000-199-XXX
BIOS test failed, cause unknown
1. Go to “Undetermined problems” on page 65.
2. Flash the system and re-test.
3. Replace component under function test.
000-250-XXX
BIOS APM failure
1. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
2. System board
001-000-XXX
System Test Passed
No action
001-00X-XXX
System Error
System board
001-01X-XXX
System Error
System board
001-024-XXX
System Addressing test failure
System board
001-025-XXX
System Checksum Value error
1. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
2. System board
001-026-XXX
System FLASH data error
1. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
2. System board
001-027-XXX
System Configuration/Setup error
1. Run the Setup Utility program.
2. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
3. System board
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
1. Reboot the system.
2. Flash the system. See “Updating (flashing) the
BIOS” on page 169.
3. Run memory test.
4. System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
Chapter 8
.
Symptom-to-FRU Index
45
Summary of Contents for THINKSTATION 7782
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Types 7782 7783 7821 7823 and 7824 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Types 7782 7783 7821 7823 and 7824 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 72: ...66 ThinkStation Hardware Maintenance Manual ...
Page 110: ...104 ThinkStation Hardware Maintenance Manual ...
Page 174: ...168 ThinkStation Hardware Maintenance Manual ...
Page 178: ...172 ThinkStation Hardware Maintenance Manual ...
Page 183: ......
Page 184: ...Part Number 0A74658 Printed in USA 1P P N 0A74658 0A74658 ...