1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 41.
3. Lay the server on its side for easier access to the system board.
4. Locate the system board and disconnect all cables connected to the system board. See “Locating
parts on the system board” on page 17.
5. Remove the heat sink and fan assembly. See “Replacing the heat sink and fan assembly” on page 77.
Note:
Place the heat sink and fan assembly on its side so that the thermal grease on the bottom of it
does not get in contact with anything.
6. Lift the small handle
1
and open the retainer
2
to access the microprocessor
3
.
Figure 65. Accessing the microprocessor
7. Lift the microprocessor straight up and out of the microprocessor socket.
Figure 66. Removing the microprocessor
84
ThinkServer TS140 Hardware Maintenance Manual
Summary of Contents for ThinkServer TS140
Page 1: ...ThinkServer TS140 Hardware Maintenance Manual Machine Types 70A0 70A1 70A4 and 70A5 ...
Page 14: ...xii ThinkServer TS140 Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TS140 Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer TS140 Hardware Maintenance Manual ...
Page 34: ...20 ThinkServer TS140 Hardware Maintenance Manual ...
Page 36: ...22 ThinkServer TS140 Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer TS140 Hardware Maintenance Manual ...
Page 116: ...102 ThinkServer TS140 Hardware Maintenance Manual ...
Page 130: ...116 ThinkServer TS140 Hardware Maintenance Manual ...
Page 131: ......
Page 132: ......