6. Install the RDX drive retainer
1
on the side of the new RDX drive. Then, slide the new RDX drive with the
retainer into the drive bay from the front of the server until the RDX drive snaps into position.
Figure 47. Installing the RDX drive
7. Connect the 4-pin power cable
1
and the signal cable
2
to the rear of the RDX drive. Connect the other
end of the power cable
1
to an available optical drive five-wire power connector. Connect the USB
connector on the other end of the signal cable
2
to the front USB 2.0 connector on the system board.
See “Locating parts on the system board” on page 17.
Figure 48. Connecting the RDX drive
8. Reinstall the front bezel. See “Removing and reinstalling the front bezel” on page 42.
9. Do one of the following:
• If you are installing an RDX drive, save the removed plastic panel from the front bezel in the event that
you later remove the drive and need the plastic panel to cover the drive bay.
• If you are replacing an RDX drive and are instructed to return the old RDX drive, follow all packaging
instructions and use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Chapter 6
.
Installing, removing, or replacing hardware
69
Summary of Contents for ThinkServer TS140
Page 1: ...ThinkServer TS140 Hardware Maintenance Manual Machine Types 70A0 70A1 70A4 and 70A5 ...
Page 14: ...xii ThinkServer TS140 Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TS140 Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer TS140 Hardware Maintenance Manual ...
Page 34: ...20 ThinkServer TS140 Hardware Maintenance Manual ...
Page 36: ...22 ThinkServer TS140 Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer TS140 Hardware Maintenance Manual ...
Page 116: ...102 ThinkServer TS140 Hardware Maintenance Manual ...
Page 130: ...116 ThinkServer TS140 Hardware Maintenance Manual ...
Page 131: ......
Page 132: ......