Diagnostic Error Code
FRU/Action
086-199-XXX
Mouse Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 64.
2. Flash the system and re-test. See “Flash update
procedures” on page 273.
3. Replace component under function test.
089-000-XXX
Microprocessor Test Passed
No action
089-XXX-XXX
Microprocessor failure
1. Microprocessor(s)
2. System board
089-195-XXX
Microprocessor Test aborted by user
Information only Restart the test, if necessary.
089-196-XXX
Microprocessor test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
089-197-XXX
Microprocessor test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
089-198-XXX
Microprocessor test aborted
1. Flash the system. See “Flash update procedures”
on page 273.
2. Go to “Undetermined problems” on page 64.
089-199-XXX
Microprocessor test failed, cause unknown
1. See “Undetermined problems” on page 64.
2. Flash the system and re-test. See “Flash update
procedures” on page 273.
3. Replace component under function test.
170-000-XXX
Voltage Sensor(s) Test Passed
No action
170-0XX-XXX
Voltage Sensor(s) failure
1. Flash system
2. System board
170-195-XXX
Voltage Sensor(s) Test aborted by user
Information only Restart the test, if necessary.
170-196-XXX
Voltage Sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
170-197-XXX
Voltage Sensor(s) test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
170-198-XXX
Voltage Sensor(s) test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Flash the system and re-test. See “Flash update
procedures” on page 273.
3. Go to “Undetermined problems” on page 64.
58
ThinkCentre Hardware Maintenance Manual
Summary of Contents for ThinkCentre M90z
Page 2: ......
Page 8: ...2 ThinkCentre Hardware Maintenance Manual ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Page 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Page 118: ...112 ThinkCentre Hardware Maintenance Manual ...
Page 278: ...272 ThinkCentre Hardware Maintenance Manual ...
Page 282: ...276 ThinkCentre Hardware Maintenance Manual ...
Page 287: ......
Page 288: ...Part Number 89Y8064 Printed in USA 1P P N 89Y8064 89Y8064 ...