Diagnostic Error Code
FRU/Action
071-199-XXX
Audio port test failed, cause unknown
1. See “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 98
3. Replace component under function test
071-25X-XXX
Audio port failure
1. Speakers
2. Audio card, if installed
3. System board
080-000-XXX
Game Port interface Test Passed
No action
080-XXX-XXX
Game Port interface Error
1. Remove the game port device and re-test the system
080-195-XXX
Game Port interface Test aborted by user
Information only Re-start the test, if necessary
080-196-XXX
Game Port interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
080-197-XXX
Game Port interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
080-198-XXX
Game Port interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 39
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 98
3. Go to “Undetermined problems” on page 64
080-199-XXX
Game Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 98
3. Replace component under function test
086-000-XXX
Mouse Port interface Test Passed
No action
086-001-XXX
Mouse Port interface Presence
1. Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller
failure
1. Mouse
2. System board
086-035-XXX
Mouse Port interface Reset
1. Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure
1. Run Setup
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Test aborted by user
Information only Re-start the test, if necessary
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7
.
Symptom-to-FRU index
57
Summary of Contents for ThinkCentre M90p
Page 1: ...ThinkCentre Hardware Maintenance Manual Machine Type 7536 ...
Page 2: ......
Page 3: ...ThinkCentre Hardware Maintenance Manual Machine Type 7536 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 44: ...38 ThinkCentre Hardware Maintenance Manual ...
Page 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Page 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Page 106: ...100 ThinkCentre Hardware Maintenance Manual ...
Page 111: ......
Page 112: ...Part Number 0A22817 Printed in USA 1P P N 0A22817 0A22817 ...