In the following index,
X
can represent any number.
Diagnostic Error Code
FRU/Action
000-000-XXX
BIOS Test Passed
No action
000-002-XXX
BIOS Timeout
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-024-XXX
BIOS Addressing test failure
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-025-XXX
BIOS Checksum Value error
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-026-XXX
FLASH data error
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-027-XXX
BIOS Configuration/Setup error
1. Run the Setup Utility program.
2. Flash the system. See “Flash update procedures”
on page 127.
3. System board
000-034-XXX
BIOS Buffer Allocation failure
1. Reboot the system.
2. Flash the system. See “Flash update procedures”
on page 127.
3. Run memory test
4. System board
000-035-XXX
BIOS Reset Condition detected
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-036-XXX
BIOS Register error
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-038-XXX
BIOS Extension failure
1. Flash the system. See “Flash update procedures”
on page 127.
2. Adapter card
3. System board
000-039-XXX
BIOS DMI data error
1. Flash the system. See “Flash update procedures”
on page 127.
2. System board
000-195-XXX
BIOS Test aborted by user
Information only Restart the test, if necessary
000-196-XXX
BIOS test halt, error threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
58
ThinkCentre Edge Hardware Maintenance Manual
Summary of Contents for ThinkCentre Edge 72z
Page 1: ...ThinkCentre Edge Hardware Maintenance Manual Machine Types 3569 3571 and 3574 ...
Page 2: ......
Page 3: ...ThinkCentre Edge Hardware Maintenance Manual Machine Types 3569 3571 and 3574 ...
Page 8: ...2 ThinkCentre Edge Hardware Maintenance Manual ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Edge Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkCentre Edge Hardware Maintenance Manual ...
Page 62: ...56 ThinkCentre Edge Hardware Maintenance Manual ...
Page 89: ...Figure 3 Locating major FRUs and CRUs Chapter 8 Locations 83 ...
Page 99: ...Figure 13 Reinstall the rubber on the foot stand Chapter 9 Replacing FRUs 93 ...
Page 132: ...126 ThinkCentre Edge Hardware Maintenance Manual ...
Page 136: ...130 ThinkCentre Edge Hardware Maintenance Manual ...
Page 141: ......
Page 142: ...Part Number Printed in USA 1P P N ...