Figure 40. Removing the seven screws that secure the system board to the main bracket
13. Place the new system board into the chassis and align the screw holes with those in the chassis.
14. Reinstall the seven screws that secure the system board to the main bracket.
15. Reinstall the rear I/O assembly. See “Replacing the rear I/O assembly” on page 99.
16. Reinstall the battery. See “Replacing the battery” on page 111.
17. Reinstall the memory modules. See “Installing or replacing a memory module” on page 113.
18. Reinstall the microprocessor. See “Replacing the microprocessor” on page 106.
19. Reinstall the heat sink assembly. See “Replacing the heat sink assembly” on page 104.
20. Reinstall the system board shield. See “Removing and reinstalling the system board shield” on page 101.
21. Reconnect all cables that were disconnected from the system board. See “Locating parts on the
system board” on page 86.
22. Go to “Completing the parts replacement” on page 124.
The failing system board must be returned with a microprocessor socket cover to protect the pins during
shipping and handling.
To install the microprocessor socket cover, do the following:
1. Release the lever securing the microprocessor retainer and open the retainer to access the
microprocessor.
2. Grasp the microprocessor on the sides and lift it straight up and out of the socket. Do not touch the
contacts on the microprocessor socket.
3. Note the orientation of the socket cover. Align the notches
1
on the microprocessor socket cover
with the alignment keys
2
on the microprocessor socket. Install one side of the socket cover into
the microprocessor socket.
118
ThinkCentre Edge Hardware Maintenance Manual
Summary of Contents for ThinkCentre Edge 72z
Page 1: ...ThinkCentre Edge Hardware Maintenance Manual Machine Types 3569 3571 and 3574 ...
Page 2: ......
Page 3: ...ThinkCentre Edge Hardware Maintenance Manual Machine Types 3569 3571 and 3574 ...
Page 8: ...2 ThinkCentre Edge Hardware Maintenance Manual ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Edge Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkCentre Edge Hardware Maintenance Manual ...
Page 62: ...56 ThinkCentre Edge Hardware Maintenance Manual ...
Page 89: ...Figure 3 Locating major FRUs and CRUs Chapter 8 Locations 83 ...
Page 99: ...Figure 13 Reinstall the rubber on the foot stand Chapter 9 Replacing FRUs 93 ...
Page 132: ...126 ThinkCentre Edge Hardware Maintenance Manual ...
Page 136: ...130 ThinkCentre Edge Hardware Maintenance Manual ...
Page 141: ......
Page 142: ...Part Number Printed in USA 1P P N ...