EIOM replacement
Use the following procedures to remove and install the Ethernet I/O module (EIOM).
The ThinkAgile CP Compute Block appliances offer connectivity to the LOM (LAN on motherboard) of each
node via ports on the EIOM located at the rear of the enclosure. The top Phy maps to port one of the system
LOM, the bottom Phy maps to port two of the system LOM.
The ports are labeled sequentially from left to right.
Figure 50. EIOM ports and corresponding node number
Table 4. EIOM port corresponding node number
1
Ports to node 1
2
Ports to node 2
3
Ports to node 3
4
Ports to node 4
Remove the EIOM
Use this information to remove the EIOM.
Before you remove the EIOM:
1. Place the node in maintenance mode.
2. Power off all compute nodes and peripheral devices.
3. Disengage all the compute nodes from the enclosure (see
http://thinksystem.lenovofiles.com/help/topic/
7X21/remove_a_compute_node_from_the_chassis.html
4. Disconnect the power cords and all external cables from the rear of the enclosure.
5. If the cable management arm is installed, remove it (see
http://thinksystem.lenovofiles.com/help/topic/
7X21/remove_the_cable_management_arm.html
6. Remove the shuttle (see
http://thinksystem.lenovofiles.com/help/topic/7X21/remove_the_shuttle.html
) and
place it on a stable work surface.
.
Part replacement and maintenance procedures
107
Summary of Contents for ThinkAgile CP
Page 4: ...ii Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 6: ...iv Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 8: ...vi Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 30: ...22 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 33: ...Chapter 4 Managing Support Mode 25 ...
Page 80: ...72 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 158: ...150 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 160: ...152 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 161: ......
Page 162: ......