MAX5” on page 209 for additional information about resolving issues indicated by those
LEDs.
The Light path power (LP2) LED is referred to as MEU LED Power in the system event log.
Light path diagnostics LEDs
Use this information to diagnose and solve possible errors that are indicated by the light path diagnostics
LEDs.
The following table describes the LEDs on the system board and suggested actions to correct detected
problems. For information about the location of the LEDs on the system board, see “Blade server controls
and LEDs” on page 7. See “Viewing the light path diagnostics LEDs” on page 203 for information about
lighting the LEDs.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path
diagnostics LED
Description
Action
None
An error has
occurred and
cannot be
isolated, the
service
processor has
failed, or the
blade server is
not sufficiently
charged to
display the LEDs
on the system
board.
1. Make sure that the light path diagnostics LED is lit, to ensure that there is
enough power in the blade server to light the rest of the LEDs. View the
media tray select LED. If it is lit, there is sufficient power in the blade
server to light the rest of the LEDs. If it is not lit, install the blade server in
a chassis for approximately 2 hours to charge the blade server (the blade
server does not have to be powered on).
See “Viewing the light path diagnostics LEDs” on page 203.
2. Check the IMM event log for information about an error that is not
represented by a light path diagnostics LED. See “IMM error codes in
AMM” on page 162.
DIMM
x
error
A memory error
occurred.
Check for system event, IMM, and AMM logs related to the memory error and
resolve these issues.
I/O expansion
error
The IMM lights
this LED when
the expansion
card in the I/O-
expansion
connector has
failed. The fault
LED on the front
panel is also lit.
1. Reseat the SSD expansion card. See “Removing an SSD expansion card”
on page 98 and “Installing an SSD expansion card” on page 99.
2. Replace the SSD expansion card. See “Removing an SSD expansion
card” on page 98 and “Installing an SSD expansion card” on page 99.
207
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...