Make sure that all cables and the console breakout cable are properly connected and secure.
Mouse problems:
Make sure that all cables and the console breakout cable are properly connected and secure.
Intermittent unexpected reboots
Note:
Some uncorrectable errors require that the server reboot so that it can disable a device, such as a
memory DIMM or a processor to allow the machine to boot up properly.
1. If the reset occurs during POST and the POST watchdog timer is enabled, make sure that sufficient time
is allowed in the watchdog timeout value (POST Watchdog Timer).
To check the POST watchdog time, restart the server and press the key according to the on-screen
instructions to display the LXPM system setup interface. (For more information, see the “Startup”
section in the LXPM documentation compatible with your server at
https://sysmgt.lenovofiles.com/help/
topic/lxpm_frontend/lxpm_product_page.html
.) Then, click
BMC Settings
➙
POST Watchdog Timer
.
2. If the reset occurs after the operating system starts, do one of the followings:
• Enter the operating system when the system operates normally and set up operating system kernel
dump process (Windows and Linux base operating systems will be using different method). Enter the
UEFI setup menus and disable the feature, or disable it with the following OneCli command.
OneCli.exe config set SystemRecovery.RebootSystemOnNMI Disable --bmc XCC_USER:XCC_PASSWORD@XCC_IPAddress
• Disable any automatic server restart (ASR) utilities, such as the Automatic Server Restart IPMI
Application for Windows, or any ASR devices that are installed.
3. See the management controller event log to check for an event code that indicates a reboot. See
for information about viewing the event log. If you are using Linux base operating
system, then capture all logs back to Lenovo support for further investigation.
Power problems
Use this information to resolve issues related to power.
System error LED is on and event log "Power supply has lost input" is displayed
To resolve the problem, ensure that:
1. The power supply is properly connected to a power cord.
2. The power cord is connected to a properly grounded electrical outlet for the server.
3. Make sure that the power supply AC source is stable within the supported range.
4. Swap the power supply to see if the issue follows the power supply, if it follows the power supply, then
replace the failing one.
5. Review the event log and see how the problem it is to follow the event log actions to resolved the
problems.
Network problems
Use this information to resolve issues related to networking.
•
“Cannot wake server using Wake on LAN” on page 112
•
“Could not log in using LDAP account with SSL enabled” on page 113
Cannot wake server using Wake on LAN
Complete the following steps until the problem is resolved:
112
ThinkSystem SR150 Maintenance Manual
Summary of Contents for 7Y54
Page 1: ...ThinkSystem SR150 Maintenance Manual Machine Type 7Y54 ...
Page 8: ...vi ThinkSystem SR150 Maintenance Manual ...
Page 25: ...Chapter 2 Server components 17 ...
Page 38: ...30 ThinkSystem SR150 Maintenance Manual ...
Page 102: ...94 ThinkSystem SR150 Maintenance Manual ...
Page 128: ...120 ThinkSystem SR150 Maintenance Manual ...
Page 132: ...124 ThinkSystem SR150 Maintenance Manual ...
Page 137: ......
Page 138: ...Part Number SP47A31793 Printed in Chinese Mainland 1P P N SP47A31793 1PSP47A31793 ...