2. If the power-on Administrator password is required, enter the password.
3. From the System Summary page, click
Update VPD
.
4. Update the UUID.
• From Lenovo XClarity Essentials OneCLI
Lenovo XClarity Essentials OneCLI sets the UUID in the Lenovo XClarity Controller. Select one of the
following methods to access the Lenovo XClarity Controller and set the UUID:
– Operate from the target system, such as LAN or keyboard console style (KCS) access
– Remote access to the target system (TCP/IP based)
To update the UUID from Lenovo XClarity Essentials OneCLI:
1. Download and install Lenovo XClarity Essentials OneCLI.
To download Lenovo XClarity Essentials OneCLI, go to the following site:
https://datacentersupport.lenovo.com/solutions/HT116433
2. Copy and unpack the OneCLI package, which also includes other required files, to the server. Make
sure that you unpack the OneCLI and the required files to the same directory.
3. After you have Lenovo XClarity Essentials OneCLI in place, type the following command to set the
UUID:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> [access_method]
Where:
<uuid_value>
Up to 16-byte hexadecimal value assigned by you.
[access_method]
The access method that you select to use from the following methods:
– Online authenticated LAN access, type the command:
[
--bmc
-username xcc_user_id
--bmc
-password xcc_password]
Where:
xcc_user_id
The BMC/IMM/XCC account name (1 of 12 accounts). The default value is USERID.
xcc_password
The BMC/IMM/XCC account password (1 of 12 accounts).
Example command is as follows:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
--bmc
-username xcc_user_id
--bmc
-password xcc_password
– Online KCS access (unauthenticated and user restricted):
You do not need to specify a value for
access_method
when you use this access method.
Example command is as follows:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
Note:
The KCS access method uses the IPMI/KCS interface, which requires that the IPMI
driver be installed.
– Remote LAN access, type the command:
[
−−bmc
xcc_user_id:xcc_password@xcc_external_ip]
234
ThinkSystem SR860 V2Setup Guide
Summary of Contents for 7X59
Page 1: ...ThinkSystem SR860 V2 Setup Guide Machine Types 7X59 and 7X60 ...
Page 8: ...vi ThinkSystem SR860 V2Setup Guide ...
Page 50: ...42 ThinkSystem SR860 V2Setup Guide ...
Page 132: ...124 ThinkSystem SR860 V2Setup Guide ...
Page 136: ...128 ThinkSystem SR860 V2Setup Guide ...
Page 154: ...146 ThinkSystem SR860 V2Setup Guide ...
Page 250: ...242 ThinkSystem SR860 V2Setup Guide ...
Page 254: ...246 ThinkSystem SR860 V2Setup Guide ...
Page 258: ...250 ThinkSystem SR860 V2Setup Guide ...
Page 259: ......
Page 260: ......