24 x 2.5-inch front drive bays (SAS/SATA)
This section provides cable routing information for the server model with 24 x 2.5-inch front drive bays (SAS/
SATA).
The server model is configured with three 8 x 2.5-inch SAS/SATA backplane (BP 1, BP 2, and BP 3). Below
lists all supported configurations with these three front drive backplanes.
Configuration
Mid or Rear BP
Storage controller
Qty.
Type
Qty.
Type
Config. 1
2
CFF 16i RAID/HBA
CFF 36i RAID Expander
Config. 2
2
SFF 8i RAID/HBA
CFF 36i RAID Expander
Config. 3
3
SFF 8i RAID/HBA
Config. 4
1
SFF 32i RAID
Config. 5
1
Rear: 4 x 2.5'' SAS/SATA
2
CFF 16i RAID/HBA
CFF 36i RAID Expander
Config. 6
1
Rear: 4 x 2.5'' SAS/SATA
2
SFF 8i RAID/HBA
CFF 36i RAID Expander
Config. 7
1
Rear: 4 x 2.5'' SAS/SATA
4
SFF 8i RAID/HBA
Config. 8
1
Rear: 4 x 2.5'' SAS/SATA
1
SFF 32i RAID
Config. 9
3
Mid: 4 x 2.5'' SAS/SATA
Mid: 4 x 2.5'' SAS/SATA
Rear: 8 x 2.5'' SAS/SATA
2
CFF 16i RAID/HBA
CFF 36i RAID Expander
Config. 10
3
Mid: 4 x 2.5'' SAS/SATA
Mid: 4 x 2.5'' SAS/SATA
Rear: 4 x 2.5'' SAS/SATA
2
CFF 16i RAID/HBA
CFF 36i RAID Expander
Config. 11
3
Mid: 4 x 2.5'' SAS/SATA
Mid: 4 x 2.5'' SAS/SATA
Rear: 4 x 2.5'' SAS/SATA
2
SFF 8i RAID/HBA
CFF 36i RAID Expander
Depending on your server configurations, refer to one of the following sections for cable routing information.
•
Configuration 1 to 4: front drive bays only
•
Configuration 5 to 8: front drive bays and rear drive bays
•
Configuration 9 to 11: front drive bays, mid drive bays, and rear drive bays
.
103
Summary of Contents for 7D2V
Page 1: ...ThinkSystem SR665 Maintenance Manual Machine Types 7D2V and 7D2W ...
Page 6: ...iv ThinkSystem SR665 Maintenance Manual ...
Page 10: ...viii ThinkSystem SR665 Maintenance Manual ...
Page 66: ...56 ThinkSystem SR665 Maintenance Manual ...
Page 82: ...Figure 25 Cable routing for configuration 4 72 ThinkSystem SR665 Maintenance Manual ...
Page 123: ...Figure 40 Cable routing for configuration 1 Chapter 3 Internal cable routing 113 ...
Page 126: ...Figure 42 Cable routing for configuration 2 116 ThinkSystem SR665 Maintenance Manual ...
Page 131: ...Figure 45 Cable routing for configuration 6 Chapter 3 Internal cable routing 121 ...
Page 133: ...Chapter 3 Internal cable routing 123 ...
Page 148: ...138 ThinkSystem SR665 Maintenance Manual ...
Page 167: ...Chapter 4 Hardware replacement procedures 157 ...
Page 237: ...Chapter 4 Hardware replacement procedures 227 ...
Page 299: ...Chapter 4 Hardware replacement procedures 289 ...
Page 300: ...On the 2 5 inch middle drive cage 290 ThinkSystem SR665 Maintenance Manual ...
Page 339: ...Chapter 4 Hardware replacement procedures 329 ...
Page 364: ...354 ThinkSystem SR665 Maintenance Manual ...
Page 408: ...398 ThinkSystem SR665 Maintenance Manual ...
Page 431: ...5 Reseat the failing device 6 Replace the failing device Chapter 5 Problem determination 421 ...
Page 444: ...434 ThinkSystem SR665 Maintenance Manual ...
Page 445: ... Copyright Lenovo 2019 435 ...
Page 448: ...438 ThinkSystem SR665 Maintenance Manual ...
Page 449: ... Copyright Lenovo 2019 439 ...
Page 452: ...442 ThinkSystem SR665 Maintenance Manual ...
Page 464: ...454 ThinkSystem SR665 Maintenance Manual ...
Page 465: ......
Page 466: ......