Supported environment
The Flex System x440 compute node complies with ASHRAE Class A3 specifications.
This is the supported operating environment:
Power on:
Temperature: 5 - 40 °C (41 - 104 °F)
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3048 m (10,000 ft.)
Maximum rate of temperature change: 5 °C/hr (41 °F/hr)
Power off:
Temperature: 5 - 45 °C (41 - 113 °F)
Relative humidity: 8 - 85%
Maximum dew point: 27 °C (80.6 °F)
Storage (non-operating):
Temperature: 1 - 60 °C (33.8 - 140 °F)
Altitude: 3050 m (10,006 ft.)
Relative humidity: 5 - 80%
Maximum dew point: 29 °C (84.2°F)
Shipment (non-operating):
Temperature: -40 - 60 °C (-40 - 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5 - 100%
Maximum dew point: 29 °C (84.2 °F)
Warranty options