Diagnostic
error
codes
Refer
to
the
following
diagnostic
error
codes
when
using
the
diagnostic
tests.
See
“Running
tests”
on
page
45
for
the
specific
type
for
information
about
the
Diagnostic
programs.
In
the
following
index,
X
can
represent
any
number.
Diagnostic
Error
Code
FRU/Action
000-000-XXX
BIOS
Test
Passed
No
action
000-002-XXX
BIOS
Timeout
1.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
2.
System
board
000-024-XXX
BIOS
Addressing
test
failure
1.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
2.
System
board
000-025-XXX
BIOS
Checksum
Value
error
1.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
2.
System
board
000-026-XXX
FLASH
data
error
1.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
2.
System
board
000-027-XXX
BIOS
Configuration/Setup
error
1.
Run
Setup
2.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
3.
System
board
000-034-XXX
BIOS
Buffer
Allocation
failure
1.
Reboot
the
system
2.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
3.
Run
memory
test
4.
System
board
000-035-XXX
BIOS
Reset
Condition
detected
1.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
2.
System
board
000-036-XXX
BIOS
Register
error
1.
Flash
the
system.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
494
2.
System
board
54
Hardware
Maintenance
Manual
Summary of Contents for 6072A5U - ThinkCentre M57 - 6072
Page 2: ......
Page 3: ...ThinkCentre Hardware Maintenance Manual ...
Page 16: ...10 Hardware Maintenance Manual ...
Page 17: ...Chapter 2 Safety information 11 ...
Page 18: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 12 Hardware Maintenance Manual ...
Page 22: ...16 Hardware Maintenance Manual ...
Page 23: ...1 2 Chapter 2 Safety information 17 ...
Page 24: ...18 Hardware Maintenance Manual ...
Page 25: ...1 2 Chapter 2 Safety information 19 ...
Page 32: ...26 Hardware Maintenance Manual ...
Page 33: ...Chapter 2 Safety information 27 ...
Page 34: ...1 2 28 Hardware Maintenance Manual ...
Page 38: ...32 Hardware Maintenance Manual ...
Page 39: ...1 2 Chapter 2 Safety information 33 ...
Page 46: ...40 Hardware Maintenance Manual ...
Page 54: ...48 Hardware Maintenance Manual ...
Page 58: ...52 Hardware Maintenance Manual ...
Page 88: ...82 Hardware Maintenance Manual ...
Page 394: ...9089 XP Pro Recovery DVDs FRU CRU Slovenian models 45R8837 1 388 Hardware Maintenance Manual ...
Page 502: ...496 Hardware Maintenance Manual ...
Page 505: ......
Page 506: ...Part Number 43C8797 Printed in USA 1P P N 43C8797 ...