Bauer
6 Specifications
GEL 2442
31
English
6 Specifications
Electrical data
Output level
1 V
pp
difference signal
Output signal
two 90° phase-shifted sinusoidal signals
and their inverse signals, short circuit
proof; optionally with reference pulse.
Output frequency
0... 200 kHz at a line capacity 5 nF
Offset (static)
± 20 mV
Amplitude tolerance
- 20% to + 10%
Amplitude ratio V
TR1
/V
TR2
0.9 .to 1.1
Supply voltage V
S
5 V DC ± 5 %
Power consumption without load
≤
0.3 W
Mechanical data
Admissible air gap
0.15 mm ± 0.02 mm with module 0.3
0.20 mm ± 0.03 mm with module 0.5
Width of the target wheel
≥
4.0 mm
Material of the target wheel
Ferromagnetic steel
Max. admissible cable length
100 m (observe the voltage drop on the
power line)
Working temperature
- 30 °C to + 85 °C
Operating and storage temperature
- 40 °C to + 120 °C
Protection class
IP 68
Electromagnetic compatibility
EN 61000-6-1 to 4
(1)
Insulation strength
500 V, according to EN 60439-1
Vibration resistance
200 m/s
2
according to DIN EN 60068-2-6
Shock resistance
2000 m/s
2
according to DIN EN
600068-2-27
Weight
30 g
Housing
Polyphenylene sulfide(PPS), glassfibre
reinforced
Connection
9-core cable, wire profile 0.15 mm
2
O.D. 5
–0.3 mm
mm, min. bending radius
25 mm.
Seperate screen connection line for near-
sensor earthing (e.g. using one fixing
screw)
(1)
The normative limit values are met if mounting and connection jobs are carried out properly. Coaxial earthing of
the MiniCoder connection cable, e.g. on the free cable end will improve noise.