Bauer
5 Electrical Connection
ESD Protection
GEL 2442
29
English
5 Electrical
Connection
5.1 ESD
Protection
ESD
(
E
lectrostatic
S
ensitive
D
evices)
For every electronic device, ESD protection is important.
This also applies to the MiniCoders. Do not touch electronic
devices unless servicing is required. This is particularly im-
portant for connector pins and loose wires. Which precau-
tions are required in the particular case is dependant on to
local situation. EN 100015-1 (CECC 00015-1) gives a com-
prehensive overview on possible solutions.
In most situations, a grounded working surface together with
ESD wrist straps will give sufficient protection.
We do recommend to check the ESD equipment regularly.
5.2
Notes on electromagnetic compatibility (EMC)
EMC
(
E
lectro
M
agnetic
C
ompatibility)
To improve the electromagnetic environment please observe the following installation
advice:
Only use connectors with metal housing or a housing made of metallised plastic
and screened cables; make sure to set up a contact between the screening and the
connector housing.
The screenings must have large-surface contact.
Keep all unscreened lines as short as possible.
Provide for earth connections being as short as possible and having a large cross-
section (e.g. low-inductance metal-alloy tape, flat-band conductor).
Keep the earth connection cable of the MiniCoder as short as possible.
If there are potential differences between machine and electronic ground straps:
Make sure that equalizing currents can flow via the cable shielding. For this purpose,
lay a large diameter voltage equalizing cable or use cables with separate two-ply
shielding, although the shielding should only be applied on one side.
The machine manufacturer has to develop an overall screening concept regarding
all the components used.